Answer:
Measuring mode means that the system is set to only measure import and export over the electricity meter. In measuring mode, the phase balancing function is disabled, and SSOs and ESOs in batteries are in sleep mode and do not feed power into the DC grid. However, the DC grid is still energized as the voltage is generated by the EnergyHub. The EnergyHub enters measurement mode when the system is stopped, either by pressing stop on the display or in EnergyCloud.
If your system is in Measuring mode for unknown reason, please contact support here.
We constantly want to improve the content in the Knowledge Database and would appreciate it if you give feedback on our articles. Does all the information exist, is there anything that needs to be clarified or is there any information that is missing that would help installing or using the Ferroamp system in general? You can give us feedback by choosing if the article was helpful or not in the options below.
If you need to get in contact with Ferroamp's Technical Support or if you have any questions about the system, you can do so by creating a ticket here.