Protokoll | Port | DNS-namn |
MQTT | TCP/1883 | data2.ferroamp.se |
Service gateway | TCP/2443 | remote-assistance-access.ferroamp.com |
NTP (Network Time Protocol) | UDP/123 | Entire internet |
DNS | TCP/53 | 8.8.8.8 |
Software updates | TCP/80 | Amazon S3 bucket in region eu-central-1 |
Answer:
The EnergyHub not being able to connect to the internet can be due to many different reasons, as outlined below:
Troubleshooting internet connection issues with the EnergyHub:
- Check that the network cable is plugged into the correct port.
- Ensure that the system has been assigned an IP address, which can be done in the display unit.
- Verify the internet connection.a
- Make sure that the firewall isn't blocking the system from sending information to the EnergyCloud. For reference, an EnergyHub requires the following outgoing traffic to be allowed:
We constantly want to improve the content in the Knowledge Database and would appreciate it if you give feedback on our articles. Does all the information exist, is there anything that needs to be clarified or is there any information that is missing that would help installing or using the EnergyHub system in general? You can give us feedback by choosing if the article was helpful or not in the options below.
If you need to get in contact with Ferroamp's Technical Support or if you have any questions about the system, you can do so by creating a ticket here.